DC energy meter with built-in current measuring sensor
TFY-CSB-CDA
Category:
Product information: TFY-CSB-CDA Product Specification V2.2.pdf
Product Description
Definition | Symbol | Value | Unit |
Primary Rated Current | Ipn | 300 | A |
Secondary Rated Current | Isn | 80 | mA |
Primary Maximum Current | Ip | 360 | A |
Secondary Output Current | Is | 80*(I/Ipn2 | mA |
Sampling Resistance (±12V@Ip) | R m | 0~20 | Ω |
Supply Voltage | Vc | ±12(±5%) | V |
Static Current Consumption (±12V @I=0A) | Ic | ≤10 | mA |
Maximum Current Consumption (±12V@I=Ip | Im | ≤120 | mA |
Accuracy (@0.011pn~0.05I pn@25℃) | XG | 0.5 | % |
Accuracy (@0.05Ipn~pn@25℃) | XG | 0.2 | % |
Static Zero Output (@I=0A.@25℃) | IoE | 5 | μA |
Zero Temperature Drift (I=0A,@-40~85℃) | VoT | 0.1 | mV/℃ |
Hysteresis Offset Voltage (@I=0A,after 1*IPN) | VOH | ≤±1 | mV |
Response Time (@90%Ipn | Tra | 5 | μS |
Bandwidth (@10%Ipn ·-3dB) | BW | >100 | kHz |
Constant Magnetic Field Influence (@200mT) | δ | ≤2 | % |
Power Frequency Magnetic Field Influence (400A/m) | δ | ≤1 | % |
Key words:
Related Products
Welcome your message consultation