Tunnel Magnetoresistance (TMR) Current Sensor (CSB-Z100 Series)

Three-Phase Direct-Connect Current Measurement Sensor for AC Energy Meters (TFY-CSB-Z100)

TFY-CSB-Z100

Category:

Product Description

SymbolNameParameter
pnRated current10A
IMAXMaximum current100A
IMSecondary rated current4mA
KNTurns ratio1:2500
XAccuracy (Ta=25℃)±0.2%
LLinearity<0.1%
di/dtTracking accuracy>100 A/μs
IoffDisplacement current±0.3mA
BWBandwidth>100kHz (-3dB)
tResponse time1 microsecond
VCSupply voltage±5V (±5%)
IcCurrent consumption2.0 mADC + I/KN
himOperating temperature-40℃~85℃
tsStorage temperature-55℃~100℃